ENCLOSURE AIR CONDITIONER

AC104-2 Enclosure Air Conditioner

Cytech · Model AC104-2

Buyer verification required

This record describes publicly documented specifications; it does not assert current production, stock or suitability. Confirm the final configuration and rated conditions with the manufacturer before purchasing.

AC104-2 by Cytech: 400 W stated cooling capacity (L35/L35); 220 V; 50 / 60 Hz; Mounting: Semi-embedded; IP55 protection rating.

Capacity is the published nominal value, not a performance ranking at a common test condition. When a webpage lists several ratings, the stated primary rating or first listed capacity/condition pair is used in the summary; check the cited page for alternatives.

Fields not yet available in this database record
  • phase

The reviewed structured fields do not contain these values. This does not mean the manufacturer has not published them elsewhere on the source page or in a document. Open the official source to check the final configuration.

COMPARISON SUMMARY

Key stated specifications

Missing values are not estimated
Rated cooling capacity
400 W
Test condition: L35/L35
Supply voltage
220 V
Supply phase
Not yet recorded
Supply frequency
50 / 60 Hz
Mounting method
Semi-embedded
Enclosure protection
IP55
Operating temperature
Not yet recorded

FIELD-LEVEL PROVENANCE

Technical specifications

Approved source-linked fields
Product name
AC104-2 Enclosure Air Conditioner
Model / configuration
AC104-2
Manufacturer
Cytech
Cooling Capacity With Rating Condition
400 W
View exact source evidence
Cooling capacity | 400W@L35/35 1360BTU/H
Open cited page ↗
Dimensions
584*354*165(mm)
View exact source evidence
Dimensions | 584*354*165(mm)
Open cited page ↗
Electrical Supply
220VAC±15% 50Hz/60Hz
View exact source evidence
Power Supply | 220VAC±15% 50Hz/60Hz
Open cited page ↗
Enclosure Rating
IP55
View exact source evidence
IP Grade | IP55
Open cited page ↗
Mounting Method
Semi-embedded Mounting
View exact source evidence
Mounting Method | Semi-embedded Mounting
Open cited page ↗
Test Condition
cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35
View exact source evidence
3 PE Protective earthing wire 8 ALR-NO Alarm output-NO 4 RS485- Communication port B- 5 RS485+ Communication port A+ Options More Option for Electrical Panel Air Conditioning 220VAC 50HZ Power Electrical Panel Air Conditioning Model Voltage Nominal cooling capacity(W) (L35/L35) Nominal cooling capacity(Btu/hr) (L35/L35) Power consumption(W)(L35/L35) IP Grade Heater (W)(option) Internal air flow (m3/h) Refrigerant Noise (dbA) CYAC103-2 220VAC 50Hz 300 1020 170 IP55,NEMA 4, NEMA 4X 500 100 R134a 56 CYAC104-2 220VAC 50Hz 400 1360 215 IP55,NEMA 4, NEMA 4X 500 110 R134a 56 CYAC105-2 220VAC 50Hz 500
Open cited page ↗

Explore more options

Products with similar stated parameters

Similarity does not mean interchangeability