ENCLOSURE AIR CONDITIONER

HSKJ4000 Enclosure Air Conditioner

Shanghai Haofuman Electrical Equipment Co., Ltd. · Model HSKJ4000

Buyer verification required

This record describes publicly documented specifications; it does not assert current production, stock or suitability. Confirm the final configuration and rated conditions with the manufacturer before purchasing.

HSKJ4000 by Shanghai Haofuman Electrical Equipment Co., Ltd.: 4000 W stated cooling capacity (test condition not recorded); Mounting: Side mounted; IP54 protection rating.

Capacity is the published nominal value, not a performance ranking at a common test condition. When a webpage lists several ratings, the stated primary rating or first listed capacity/condition pair is used in the summary; check the cited page for alternatives.

Fields not yet available in this database record
  • phase

The reviewed structured fields do not contain these values. This does not mean the manufacturer has not published them elsewhere on the source page or in a document. Open the official source to check the final configuration.

COMPARISON SUMMARY

Key stated specifications

Missing values are not estimated
Rated cooling capacity
4000 W
Test condition not recorded
Supply phase
Not yet recorded
Mounting method
Side mounted
Enclosure protection
IP54
Operating temperature
-5 to 55 °C

FIELD-LEVEL PROVENANCE

Technical specifications

Approved source-linked fields
Product name
HSKJ4000 Enclosure Air Conditioner
Model / configuration
HSKJ4000
Cooling Capacity With Rating Condition
4000 W
View exact source evidence
HSKJ4000 | 4000 | AC220±10%,50/60 | 453*1230*275 | 8.6 | 1880 | 600/850 | 80
Open cited page ↗
Dimensions
453*1230*275

Data note: Official column specifies width x height x depth in mm. No axis order is inferred from the product name.

View exact source evidence
HSKJ4000 | 4000 | AC220±10%,50/60 | 453*1230*275 | 8.6 | 1880 | 600/850 | 80
Open cited page ↗
Enclosure Rating
IP54
View exact source evidence
HSKJ series high temperature cabinet air conditioning technical parameters Model Refrigerating capacity (W) Operating voltage (v,Hz) Overall dimension width × height × depth (mm) Rated current (A) Rated power (W) Internal/external circulating air volume (m³/h) Weight (KG) Working environment temperature Refrigerant Protection level Color Installation method Adjustable temperature range HSKJ300 300 AC220±10%,50 286*445*173 1.2 260 60/150 15 -5°C ~ 55°C R134a IP54 RAL7035 Wall-mounted vertical installation 24°C ~ 45°C (factory set temperature 28°C, return temperature 5°C, start at 33°C, stop at 28°C) HSKJ450 450 AC220±10%,50 286*500*173 1.5 290 100/180 17 HSKJ500 500 AC220±10%,50 286*500*173 1.8 320 100/180 18 HSKJ600 600 AC220±10%,50 350*630*203 2.1 450 120/210 26 HSKJ800 800 AC220±10%,50 350*630*203 2.3 500 150/210 28 HSKJ1000 1000 AC220±10%,50/60 370*855*231 3.5 770 180/320 35 HSKJ1200 1200 AC220±10%,50/60 370*855*231 3.7 800 200/550 37 HSKJ1500 1500 AC220±10%,50/60 370*855*231 4.3 950 350/550 39 HSKJ2000 2000 AC220±10%,50/60 435*1160*275 5 1070 450/750 65 HSKJ2500 2500 AC220±10%,50/60 435*1160*275 6.3 1400 500/750 70 HSKJ3200 3200 AC220±10%,50/60 453*1230*275 7.3 1700 550/750 75 HSKJ3500 3500 AC220±10%,50/60 453*1230*275 7.9 1760 600/850 78 HSKJ4000 4000 AC220±10%,50/60 453*1230*275 8.6 1880 600/850 80
Open cited page ↗
Input Power
1880 W
View exact source evidence
HSKJ4000 | 4000 | AC220±10%,50/60 | 453*1230*275 | 8.6 | 1880 | 600/850 | 80
Open cited page ↗
Mounting Method
Wall-mounted vertical installation
View exact source evidence
HSKJ series high temperature cabinet air conditioning technical parameters Model Refrigerating capacity (W) Operating voltage (v,Hz) Overall dimension width × height × depth (mm) Rated current (A) Rated power (W) Internal/external circulating air volume (m³/h) Weight (KG) Working environment temperature Refrigerant Protection level Color Installation method Adjustable temperature range HSKJ300 300 AC220±10%,50 286*445*173 1.2 260 60/150 15 -5°C ~ 55°C R134a IP54 RAL7035 Wall-mounted vertical installation 24°C ~ 45°C (factory set temperature 28°C, return temperature 5°C, start at 33°C, stop at 28°C) HSKJ450 450 AC220±10%,50 286*500*173 1.5 290 100/180 17 HSKJ500 500 AC220±10%,50 286*500*173 1.8 320 100/180 18 HSKJ600 600 AC220±10%,50 350*630*203 2.1 450 120/210 26 HSKJ800 800 AC220±10%,50 350*630*203 2.3 500 150/210 28 HSKJ1000 1000 AC220±10%,50/60 370*855*231 3.5 770 180/320 35 HSKJ1200 1200 AC220±10%,50/60 370*855*231 3.7 800 200/550 37 HSKJ1500 1500 AC220±10%,50/60 370*855*231 4.3 950 350/550 39 HSKJ2000 2000 AC220±10%,50/60 435*1160*275 5 1070 450/750 65 HSKJ2500 2500 AC220±10%,50/60 435*1160*275 6.3 1400 500/750 70 HSKJ3200 3200 AC220±10%,50/60 453*1230*275 7.3 1700 550/750 75 HSKJ3500 3500 AC220±10%,50/60 453*1230*275 7.9 1760 600/850 78 HSKJ4000 4000 AC220±10%,50/60 453*1230*275 8.6 1880 600/850 80
Open cited page ↗
Operating Temperature
-5°C ~ 55°C
View exact source evidence
HSKJ series high temperature cabinet air conditioning technical parameters Model Refrigerating capacity (W) Operating voltage (v,Hz) Overall dimension width × height × depth (mm) Rated current (A) Rated power (W) Internal/external circulating air volume (m³/h) Weight (KG) Working environment temperature Refrigerant Protection level Color Installation method Adjustable temperature range HSKJ300 300 AC220±10%,50 286*445*173 1.2 260 60/150 15 -5°C ~ 55°C R134a IP54 RAL7035 Wall-mounted vertical installation 24°C ~ 45°C (factory set temperature 28°C, return temperature 5°C, start at 33°C, stop at 28°C) HSKJ450 450 AC220±10%,50 286*500*173 1.5 290 100/180 17 HSKJ500 500 AC220±10%,50 286*500*173 1.8 320 100/180 18 HSKJ600 600 AC220±10%,50 350*630*203 2.1 450 120/210 26 HSKJ800 800 AC220±10%,50 350*630*203 2.3 500 150/210 28 HSKJ1000 1000 AC220±10%,50/60 370*855*231 3.5 770 180/320 35 HSKJ1200 1200 AC220±10%,50/60 370*855*231 3.7 800 200/550 37 HSKJ1500 1500 AC220±10%,50/60 370*855*231 4.3 950 350/550 39 HSKJ2000 2000 AC220±10%,50/60 435*1160*275 5 1070 450/750 65 HSKJ2500 2500 AC220±10%,50/60 435*1160*275 6.3 1400 500/750 70 HSKJ3200 3200 AC220±10%,50/60 453*1230*275 7.3 1700 550/750 75 HSKJ3500 3500 AC220±10%,50/60 453*1230*275 7.9 1760 600/850 78 HSKJ4000 4000 AC220±10%,50/60 453*1230*275 8.6 1880 600/850 80
Open cited page ↗
Rated Current
8.6 A
View exact source evidence
HSKJ4000 | 4000 | AC220±10%,50/60 | 453*1230*275 | 8.6 | 1880 | 600/850 | 80
Open cited page ↗
Stated Electrical Supply
AC220±10%,50/60

Literal source statement; options, units or source differences require verification. Not used for parameter filtering.

Data note: Supply is reproduced under the manufacturer column labelled v,Hz. Combined alternatives and tolerance are not converted to one supply configuration.

View exact source evidence
HSKJ4000 | 4000 | AC220±10%,50/60 | 453*1230*275 | 8.6 | 1880 | 600/850 | 80
Open cited page ↗

Explore more options

Products with similar stated parameters

Similarity does not mean interchangeability
Enclosure Air Conditioner

HSKJ3500 Enclosure Air Conditioner

Shanghai Haofuman Electrical Equipment Co., Ltd. · HSKJ3500

Cooling
3500 W
Test condition not recorded
Rating
IP54

Why shown: same mounting method; same stated protection rating; published nominal cooling capacity within 15%; check conditions. These similarities do not establish compatibility.

View sourced specifications →