ENCLOSURE AIR CONDITIONER

SKW1500 Enclosure Air Conditioner

Shanghai Haofuman Electrical Equipment Co., Ltd. · Model SKW1500

Buyer verification required

This record describes publicly documented specifications; it does not assert current production, stock or suitability. Confirm the final configuration and rated conditions with the manufacturer before purchasing.

SKW1500 by Shanghai Haofuman Electrical Equipment Co., Ltd.: 1500 W stated cooling capacity (test condition not recorded); Mounting: Side mounted; IP54 protection rating.

Capacity is the published nominal value, not a performance ranking at a common test condition. When a webpage lists several ratings, the stated primary rating or first listed capacity/condition pair is used in the summary; check the cited page for alternatives.

Fields not yet available in this database record
  • phase

The reviewed structured fields do not contain these values. This does not mean the manufacturer has not published them elsewhere on the source page or in a document. Open the official source to check the final configuration.

COMPARISON SUMMARY

Key stated specifications

Missing values are not estimated
Rated cooling capacity
1500 W
Test condition not recorded
Supply phase
Not yet recorded
Mounting method
Side mounted
Enclosure protection
IP54
Operating temperature
-15 to 55 °C

FIELD-LEVEL PROVENANCE

Technical specifications

Approved source-linked fields
Product name
SKW1500 Enclosure Air Conditioner
Model / configuration
SKW1500
Cooling Capacity With Rating Condition
1500 W
View exact source evidence
SKW1500 | 1500 | AC220,50/60 | 400*950*280 | 3.5 | 750 | 850/900 | 41
Open cited page ↗
Dimensions
400*950*280

Data note: Official column specifies width x height x depth in mm. No axis order is inferred from the product name.

View exact source evidence
SKW1500 | 1500 | AC220,50/60 | 400*950*280 | 3.5 | 750 | 850/900 | 41
Open cited page ↗
Enclosure Rating
IP54
View exact source evidence
SKW series anhydrous cabinet air conditioning technical parameters Model Refrigerating capacity (W) Operating voltage (v,Hz) Overall dimension width × height × depth (mm) Rated current (A) Rated power (W) Internal/external circulating air volume (m³/h) Weight (KG) Temperature adjustment Section Scope Working ring ambient temperature range Refrigerant Protection level Color Installation method Factory set temperature SKW500 500 AC220,50/60 280*550*210 1.3 260 120/180 17 15°C ~ 55°C -15°C ~ 55°C R134a IP54 RAL7035 Wall-mounted vertical installation 35°C SKW1000 1100 AC220,50/60 400*950*280 2.5 540 850/900 41 SKW1500 1500 AC220,50/60 400*950*280 3.5 750 850/900 41 SKW2000 2000 AC220,50/60 400*950*280 4.6 1000 850/900 41 SKW2500 2500 AC220,50/60 400*950*280 5.1 1100 850/900 41
Open cited page ↗
Input Power
750 W
View exact source evidence
SKW1500 | 1500 | AC220,50/60 | 400*950*280 | 3.5 | 750 | 850/900 | 41
Open cited page ↗
Mounting Method
Wall-mounted vertical installation
View exact source evidence
SKW series anhydrous cabinet air conditioning technical parameters Model Refrigerating capacity (W) Operating voltage (v,Hz) Overall dimension width × height × depth (mm) Rated current (A) Rated power (W) Internal/external circulating air volume (m³/h) Weight (KG) Temperature adjustment Section Scope Working ring ambient temperature range Refrigerant Protection level Color Installation method Factory set temperature SKW500 500 AC220,50/60 280*550*210 1.3 260 120/180 17 15°C ~ 55°C -15°C ~ 55°C R134a IP54 RAL7035 Wall-mounted vertical installation 35°C SKW1000 1100 AC220,50/60 400*950*280 2.5 540 850/900 41 SKW1500 1500 AC220,50/60 400*950*280 3.5 750 850/900 41 SKW2000 2000 AC220,50/60 400*950*280 4.6 1000 850/900 41 SKW2500 2500 AC220,50/60 400*950*280 5.1 1100 850/900 41
Open cited page ↗
Operating Temperature
-15°C ~ 55°C
View exact source evidence
SKW series anhydrous cabinet air conditioning technical parameters Model Refrigerating capacity (W) Operating voltage (v,Hz) Overall dimension width × height × depth (mm) Rated current (A) Rated power (W) Internal/external circulating air volume (m³/h) Weight (KG) Temperature adjustment Section Scope Working ring ambient temperature range Refrigerant Protection level Color Installation method Factory set temperature SKW500 500 AC220,50/60 280*550*210 1.3 260 120/180 17 15°C ~ 55°C -15°C ~ 55°C R134a IP54 RAL7035 Wall-mounted vertical installation 35°C SKW1000 1100 AC220,50/60 400*950*280 2.5 540 850/900 41 SKW1500 1500 AC220,50/60 400*950*280 3.5 750 850/900 41 SKW2000 2000 AC220,50/60 400*950*280 4.6 1000 850/900 41 SKW2500 2500 AC220,50/60 400*950*280 5.1 1100 850/900 41
Open cited page ↗
Rated Current
3.5 A
View exact source evidence
SKW1500 | 1500 | AC220,50/60 | 400*950*280 | 3.5 | 750 | 850/900 | 41
Open cited page ↗
Stated Electrical Supply
AC220,50/60

Literal source statement; options, units or source differences require verification. Not used for parameter filtering.

Data note: Supply is reproduced under the manufacturer column labelled v,Hz. Combined alternatives and tolerance are not converted to one supply configuration.

View exact source evidence
SKW1500 | 1500 | AC220,50/60 | 400*950*280 | 3.5 | 750 | 850/900 | 41
Open cited page ↗

Explore more options

Products with similar stated parameters

Similarity does not mean interchangeability
Enclosure Air Conditioner

HSKJ1500 Enclosure Air Conditioner

Shanghai Haofuman Electrical Equipment Co., Ltd. · HSKJ1500

Cooling
1500 W
Test condition not recorded
Rating
IP54

Why shown: same mounting method; same stated protection rating; published nominal cooling capacity within 15%; check conditions. These similarities do not establish compatibility.

View sourced specifications →